3. StellarMate Pro X
3.1. Safety Information
Read this section before using StellarMate Pro X, and keep it for future reference.
Danger
Never look at the Sun through a telescope, finder or camera without a certified solar filter fitted securely over the front of the optics. Doing so causes immediate, permanent eye damage and can destroy your camera and equipment.
Warning
Input voltage. StellarMate Pro X runs on 12 V DC (operating range 11-14 V). Never supply more than 15 V DC. Higher voltages can permanently damage the unit and the equipment connected to it.
Warning
Output voltage follows input voltage. The 12 V DC and dew heater outputs pass the input voltage through unregulated, and the stepper motor is driven from the input voltage. If your supply or battery is above the voltage your equipment accepts, that equipment can be permanently damaged.
Caution
Hot surface. StellarMate Pro X has no fan. Its aluminium enclosure is the heat sink and can become hot to the touch during normal operation. Allow the unit to cool before handling it, and do not cover it or place it in a closed box while it is running.
Caution
No user-serviceable parts. Do not open the enclosure or attempt repairs. Opening the unit voids the warranty and can damage internal components. Do not expose the unit to rain, dew or liquids.
3.2. Introduction
Thank you for purchasing StellarMate Pro X. StellarMate Pro X (SM Pro X) is an astrophotography controller from Ikarus Technologies that replaces the separate computer, power box, focus controller and GPS receiver on your telescope with a single unit. It combines a fanless Intel N100 computer, a smart power distribution hub, a stepper focuser controller and a multi-constellation GPS receiver in one sealed, CNC-machined aluminium enclosure measuring 165 x 125 x 34 mm.
SM Pro X has an Intel N100 quad-core processor, 8 GB of LPDDR5 memory and a 256 GB NVMe SSD. This makes it well suited to demanding deep-sky imaging, high-resolution cooled cameras and multi-camera setups. It comes preloaded with StellarMate OS, including KStars, Ekos and the full INDI driver library, so no additional software is required.
As a power hub, SM Pro X provides software-controlled outputs for your whole imaging train:
Four switched 12 V DC outputs.
Two 12 V PWM outputs for dew heaters.
One adjustable 3-9 V DC output.
One USB-C Power Delivery (PD) output, up to 60 W.
A stepper motor output that drives a focuser motor directly.
Wi-Fi 6E, Bluetooth 5.3 and Gigabit Ethernet provide fast, reliable communication between SM Pro X and your tablet, phone or computer. The built-in GPS receiver provides accurate location and time, whether you are in the field or in a permanent observatory.
Note
A power supply is not included. SM Pro X requires a regulated 12 V DC supply rated at 10 A or higher. The official StellarMate Pro Power Supply (IKA-834) is certified for use with SM Pro X.
3.2.1. Ways to Control StellarMate Pro X
StellarMate App (recommended): Control SM Pro X over Wi-Fi from the StellarMate App for Android and iOS. For the best experience, use a tablet with a screen of 10 inches or larger. Phones are supported, but the app is optimized for tablets.
KStars/Ekos on Windows, macOS or Linux: Control SM Pro X remotely over Wi-Fi, a local network (LAN) or the internet (WAN). Ekos adds advanced features such as the mosaic planner and the scheduler. See Connecting from a Computer.
Standalone: SM Pro X is a complete computer. Connect a monitor over HDMI, plus a keyboard and mouse, to use StellarMate OS directly. Because SM Pro X is usually mounted on the telescope, this method is mainly useful for setup and troubleshooting.
3.2.2. Getting Started at a Glance
Mount SM Pro X on your telescope or mount and attach the antennas.
Connect your equipment (mount, cameras, focuser, filter wheel, and so on) to SM Pro X over USB.
Power your equipment from the SM Pro X power outputs.
Connect to SM Pro X from the StellarMate App or from KStars/Ekos on your computer.
Start your equipment profile and begin imaging.
3.3. Specifications
StellarMate Pro X (model SM-180, part number IKA-870-256GB) comes with 8 GB RAM and 256 GB NVMe storage.
Operating System |
StellarMate OS (KStars, Ekos and INDI pre-installed) |
Processor |
Intel N100, 4 cores |
Graphics |
Intel UHD Graphics |
Memory |
8 GB LPDDR5 |
Storage |
256 GB NVMe SSD (M.2 2230) |
Wireless |
|
Wired Network |
Gigabit Ethernet (RJ45) |
GPS |
Built-in multi-constellation receiver (GPS, GLONASS, Galileo, BeiDou) with SMA antenna port |
USB |
|
Video Output |
1x HDMI |
Power Input |
XT-60, 12 V DC nominal, 11-14 V operating range, 15 V maximum. Regulated 12 V 10 A (120 W) supply or 12 V battery. Reverse polarity protection. |
Power Outputs |
|
Focuser |
Stepper motor output, RJ45. TMC2209 driver for two-phase bipolar motors, up to 1.15 A RMS, 1/1 to 1/256 microstepping |
Auxiliary Port |
3.5 mm 4-pole (TRRS) jack, I2C, for the Ikarus Temperature and Humidity Sensor and compatible accessories |
Cooling |
Fanless. The enclosure acts as the heat sink. |
Enclosure |
CNC-machined 6061-T6 aluminium, sand-blasted and anodized |
Dimensions |
164.6 x 124.6 x 34.0 mm (excluding antennas and connectors) |
Mounting |
Top and bottom faces: 6x M6 and 1x 1/4”-20 threaded holes each. See Mounting. |
Operating Temperature |
0 °C to 35 °C (rated) |
Compliance |
FCC, CE, UKCA, RCM, RoHS, WEEE. Contains FCC ID: TX2-RTL8852CE. |
3.4. Package Contents
The StellarMate Pro X box contains:
Item |
Quantity |
|---|---|
StellarMate Pro X unit |
1 |
Wi-Fi antenna, SMA, 3 dBi |
2 |
GPS antenna, SMA (passive) |
1 |
XT-60 to DC female power adapter cable |
1 |
DC cable, 5.5 x 2.1 mm male to male, 100 cm |
1 |
DC cable, 5.5 x 2.1 mm male to male, 50 cm |
1 |
Quick Start Guide |
1 |
EkosLive offer card |
1 |
If any item is missing or damaged, contact StellarMate Support.
The following accessories are sold separately:
3.5. Ports and Indicators
SM Pro X has three connector panels:
Power panel: power input, all power outputs, the stepper port and the status LEDs.
Communication panel: GPS antenna, auxiliary port, factory reset button, USB, HDMI and Ethernet.
Antenna panel: the two Wi-Fi antenna connectors.
# |
Port |
Connector |
Notes |
|---|---|---|---|
1 |
12 V DC Power Input |
XT-60 |
See Power |
2 |
4x 12 V DC Output |
5.5 x 2.1 mm, center positive |
Switched on/off in software |
3 |
2x 12 V PWM Output |
RCA |
Dew heaters, duty cycle 0-100% |
4 |
3-9 V Variable DC Output |
5.5 x 2.1 mm, center positive |
Voltage set in software |
5 |
Stepper Output |
RJ45 |
Focuser motor. Not a network port. See Stepper Port |
6 |
GPS Antenna |
SMA |
See GPS |
7 |
Auxiliary Port |
3.5 mm TRRS jack |
I2C sensors |
8 |
Factory Reset |
Recessed button |
See Factory Reset |
9 |
4x USB 3.2 |
Type-A |
Cameras and high-bandwidth devices |
10 |
2x USB 2.0 |
Type-A |
Focusers, filter wheels, mount adapters, dongles |
11 |
HDMI Output |
HDMI Type-A |
External monitor |
12 |
USB-C |
USB Type-C |
Data and Power Delivery up to 60 W |
13 |
Gigabit Ethernet |
RJ45 |
Wired network |
14, 15 |
Wi-Fi Antennas |
SMA |
Antenna panel |
3.5.1. Status Indicators
Eleven LEDs on the power panel show the state of the unit and of each power output.
LED |
Meaning |
|---|---|
PWR |
Double-pulse heartbeat while StellarMate OS is starting. Solid when the unit is running normally. |
ACT |
Flickers with processor activity. Most visible during startup. |
NVMe |
Blinks with storage activity. |
GPS |
Slow breathing pulse while searching for satellites. Solid when a 3D fix is obtained. If the LED goes off, there is no fix yet; check the GPS status in StellarMate App. |
DC 12V Out 1-4 |
On when the corresponding 12 V output is on. |
PWM 12V Out 1-2 |
On when the corresponding dew heater output is on. |
DC 3-9V Out |
On when the variable output is on. |
Tip
To keep the observing site dark, turn all LEDs off from the Power tab in StellarMate App or the SM Pro X driver in Ekos. The buzzer can be turned off in the same place.
3.6. Setting Up StellarMate Pro X
Mount the unit. Attach SM Pro X to your telescope, mount or pier as described in Mounting.
Attach the antennas. Screw the GPS antenna onto the GPS SMA connector on the communication panel, and the two Wi-Fi antennas onto the SMA connectors on the antenna panel. Tighten them by hand only.
Warning
Do not swap the GPS and Wi-Fi antennas, and do not remove antennas while the unit is powered. Doing so may cause a loss of communication.
Connect your equipment. Connect your cameras to the USB 3.2 ports, and your focuser, filter wheel, mount adapter and dongles to the USB 2.0 ports.
Connect equipment power. Connect your equipment to the 12 V DC, PWM and variable outputs using the supplied 5.5 x 2.1 mm cables or your own cables. Check that the total current stays within your power supply rating (see Power Budget).
Connect the power supply. Plug the XT-60 power adapter into the 12 V DC input, and connect the adapter’s DC jack to a regulated 12 V supply or battery rated at 10 A or higher. Alternatively, connect the StellarMate Pro Power Supply (IKA-834) directly to the XT-60 input.
Power on. Turn on your power supply. The PWR LED starts a heartbeat pattern and the ACT and NVMe LEDs flicker. After 20-30 seconds, two beeps indicate that the unit is ready and the StellarMate hotspot is available.
Register and connect. Install StellarMate App from the App Store or Google Play. Register your unit by scanning the QR code on the bottom of SM Pro X. Then connect your tablet to the StellarMate hotspot, tap RESCAN, select your StellarMate Pro X, and create your first equipment profile.
Note
Your tablet must be connected to the internet during registration. After registration, StellarMate works fully offline.
Network name (SSID) |
|
Password |
|
Band |
5 GHz |
3.7. Mounting
SM Pro X has a rugged CNC-machined aluminium enclosure measuring 164.6 x 124.6 x 34.0 mm (length x width x height, excluding antennas and connectors). Leave free space in front of each panel for cable plugs and their bend radius.
The top and bottom faces have the same pattern of threaded mounting holes, so you can mount the unit either way up:
6x M6 threads: two holes 95 mm apart (A1, A2), and four holes in a 20 x 20 mm square at the center (A3-A6).
1x 1/4”-20 thread (standard camera/tripod thread) at the center (B1).
All holes are blind, so the enclosure stays sealed.
Warning
Maximum screw engagement: 9 mm on the top face, 6 mm on the bottom face. Longer screws bottom out in the blind holes and can damage the threads or the enclosure. Choose a screw no longer than the thickness of your bracket plus the maximum engagement. For a secure hold, aim for at least 5 mm of engagement.
Ikarus Universal Vixen/Losmandy Clamp
The Ikarus Universal Vixen/Losmandy Clamp (sold separately) attaches to the top of the unit with M6 screws. The clamp then secures SM Pro X to a Vixen or Losmandy dovetail on your mount or telescope.
Other brackets
For loads with vibration or leverage, use at least two M6 screws: either the two holes 95 mm apart, or the four holes in the center square.
The single 1/4”-20 thread is intended for light-duty, camera-style mounts. Add an M6 screw to stop the unit from rotating.
Prefer metal brackets with good surface contact. The top and bottom covers dissipate the unit’s heat, so do not mount the unit against heat-sensitive surfaces, wrap it, or place it inside a closed box.
3.8. Power
3.8.1. Power Input
SM Pro X is powered through the XT-60 connector on the power panel. Use the supplied XT-60 power adapter to connect a supply with a 5.5 x 2.1 mm DC plug.
Nominal voltage |
12 V DC |
Operating range |
11-14 V DC |
Maximum voltage |
15 V DC. Never exceed this voltage. |
Recommended supply |
Regulated 12 V DC, 10 A (120 W) or higher, or a 12 V battery. The StellarMate Pro Power Supply (IKA-834) is certified for SM Pro X. |
Protection |
Reverse polarity protection. Over-voltage protection for the internal computer. |
The operating range covers regulated 12 V supplies, lead-acid batteries and LiFePO4 batteries. Below 11 V the unit and your equipment may reset. Above 14 V, SM Pro X does not switch on the 12 V DC and dew heater outputs by default (see Over-Voltage Limit below).
Warning
The 12 V DC and dew heater outputs are not regulated: their voltage is the same as the input voltage. The stepper motor is also driven from the input voltage. The input over-voltage protection protects the internal computer only, not these outputs. Only connect equipment that accepts the voltage of your power supply or battery.
3.8.2. Power Outputs
Output |
Ports |
Voltage |
Max Current |
Control |
Typical Use |
|---|---|---|---|---|---|
12 V DC Out |
4 |
Same as input |
3 A per port |
On/off |
Mount, cooled camera, accessories |
PWM (Dew) Out |
2 |
Same as input, PWM |
3 A per port |
Duty cycle 0-100% |
Dew heaters |
Variable Out |
1 |
3-9 V adjustable |
3 A |
Voltage set in software |
DSLR dummy battery, low-voltage equipment |
Stepper |
1 |
Same as input |
1.15 A RMS |
Focuser driver |
Focuser motor |
USB-C PD |
1 |
Negotiated with device |
60 W |
Always on |
Laptops, phones, USB-C powered equipment |
USB 3.2 |
4 |
5 V |
1.5 A per port |
On/off |
Cameras |
USB 2.0 |
2 |
5 V |
0.5 A per port |
On/off |
Focusers, filter wheels, dongles |
Toggle the outputs and USB ports, set the dew heater duty cycle and set the variable voltage from the Power tab in StellarMate App, or from the SM Pro X driver in Ekos.
3.8.3. Power Budget
SM Pro X and all the equipment it powers share one power supply. The per-port ratings above add up to more than any single supply can deliver, so plan your setup so that the total current stays within your supply’s rating.
Inside the unit, power is split into two protected circuits:
Power outputs: the 12 V DC, dew heater, variable, stepper and USB-C PD outputs share a 10 A internal fuse. Their combined current must stay below 10 A, even with a larger power supply.
Computer and USB ports: the internal computer and all six USB ports are on a separate circuit.
The fuses are inside the sealed enclosure and are not user-replaceable. If all power outputs stop working while the unit keeps running, contact StellarMate Support.
To estimate your total current from the 12 V supply, add up:
Load |
Typical current at 12 V |
|---|---|
SM Pro X itself |
1-1.5 A |
Mount |
1-3 A, highest while slewing |
Cooled camera |
1-3 A, highest at full cooling |
Dew heater strip |
0.5-1.5 A each at 100% duty cycle |
USB-powered devices |
About half of their 5 V current. For example, 2 A at 5 V is about 1 A at 12 V |
USB-C PD device |
Up to 5.5 A for a 60 W device |
Check the actual figures in the specifications of your equipment.
Example with the 10 A StellarMate Pro Power Supply: SM Pro X 1.5 A + mount 2 A + cooled camera 3 A + two dew heaters at 1 A each = 8.5 A. This leaves a small margin. Adding a laptop on the USB-C PD port would exceed the supply rating.
If the total current is too high, the supply voltage drops or the supply shuts down, and the unit and your equipment may reset in the middle of a session.
Monitoring: the Power tab in StellarMate App shows the input voltage, the total current and the current of each 12 V and dew heater output. Use it to check your actual consumption during a session. The total current reading covers the 12 V and dew heater outputs; it does not include the unit itself, the USB ports, the variable output or the USB-C PD port.
3.8.4. Over-Voltage Limit
The over-voltage protection setting in StellarMate App > Power tab (or Over Voltage in the SM Pro X driver in Ekos) sets the highest input voltage at which SM Pro X will switch on the 12 V DC outputs and the dew heater outputs. The default is 14 V, and it can be set from 10 V to 15 V. If the input voltage is above this limit, the outputs are not switched on.
The Power tab also shows the input voltage reported by the unit, so you can compare it with the limit. Set the limit to the maximum voltage your connected 12 V equipment accepts. For example, if your camera accepts 11-13 V, set the limit to 13 V.
3.8.5. Output State at Startup
The power outputs stay off until StellarMate OS has started. Once the unit is ready, the last saved state of each output is restored automatically: which outputs are on, the dew heater duty cycles and the variable voltage.
Note
If GPS Recovery is enabled (the default) and there is no GPS fix shortly after startup, the outputs and USB 3.2 ports are turned off for up to about a minute while the GPS receiver gets a fix, and are then restored. See GPS.
3.9. Startup and Shutdown
3.9.1. Startup
SM Pro X starts automatically when power is applied. A cold start takes 20-30 seconds:
The PWR LED shows a heartbeat pattern and the ACT and NVMe LEDs flicker while StellarMate OS starts.
Two beeps indicate the unit is ready. The PWR LED turns solid and the StellarMate hotspot becomes available.
The last saved state of the power outputs is restored.
Once the unit is ready, connect to it from StellarMate App or KStars/Ekos, then start your equipment profile or run a schedule with the Scheduler.
3.9.2. Shutdown
Always shut down SM Pro X from StellarMate App or from StellarMate OS before disconnecting power. Removing power while the unit is running can corrupt data on the SSD, including images that are still being saved.
3.10. Connecting from a Computer
You can control SM Pro X remotely from a Windows, macOS or Linux computer running KStars/Ekos, over Wi-Fi or Gigabit Ethernet. You can also access the StellarMate OS desktop over the local network with Remote Desktop, or over the internet with RustDesk. See Remote Control for details.
If you create equipment profiles in StellarMate App, the SM Pro X power driver is added to your profile automatically. If you create a profile directly in Ekos (on your computer, or on SM Pro X over Remote Desktop), add the driver in the Remote field of the profile editor:
@localhost:12624
Note
The StellarMate Control Panel (StellarMate Dashboard) is available at http://stellarmate.local from any browser on the same network. Use it to check system health and services, manage the network, and back up or restore your settings.
3.11. GPS
SM Pro X has a built-in multi-constellation receiver (GPS, GLONASS, Galileo and BeiDou) with an SMA antenna connector on the communication panel. A passive GPS antenna is included. Once the receiver has a fix, it provides your location and accurate UTC time, and both are applied to the unit automatically. GPS works best outdoors with a clear view of the sky.
The GPS LED on the power panel shows the receiver status:
Slow breathing pulse: searching for satellites.
Solid: a 3D fix has been obtained.
You can also check the fix status in the Power tab of StellarMate App.
3.11.1. USB 3 Interference
USB 3 devices and cables emit radio noise in the same frequency band as GPS. This noise can prevent the receiver from getting a fix, especially with the small passive antenna.
To reduce interference:
Use double-shielded USB 3 cables.
Keep the GPS antenna as far as possible from USB 3 cables, cameras, SSDs and hubs.
Use an active antenna mounted away from the unit (see below).
GPS Recovery
The SM Pro X driver includes a GPS Recovery feature, enabled by default in the driver’s GPS tab. If there is no fix shortly after startup, the driver temporarily turns off the power outputs and the USB 3.2 ports to remove interference, resets the GPS receiver, and waits up to 60 seconds for a fix. It then restores all outputs to their previous state, whether or not a fix was obtained.
If you prefer your equipment to stay powered at startup, disable GPS Recovery in the driver.
3.11.2. Active GPS Antenna
If the passive antenna cannot get a fix, use an active antenna. The Ikarus Active GPS Antenna (IKA-860) is recommended.
Mount the active antenna at least 50 cm away from SM Pro X and from USB 3 devices and cables (cameras, SSDs, hubs), ideally with a clear view of the sky.
In StellarMate App, tap the GPS status indicator in the Power tab and switch the antenna type to Active. An active antenna that is not powered receives almost no signal.
3.12. Auxiliary Port
The auxiliary (AUX) port is a 3.5 mm 4-pole (TRRS) jack on the communication panel. It connects external sensors and accessories over I2C, provided the accessory is supported by StellarMate OS. The port hardware also supports 1-Wire, which is reserved for future use. The port supplies 3.3 V at up to about 180 mA to the connected accessory.
For temperature and humidity data, use the Ikarus Temperature and Humidity Sensor (IKA-855). This sensor is required for some features, including automatic dew control. When a supported sensor is detected, the Environment tab of the SM Pro X driver becomes available.
3.12.1. Pinout
Plug Contact |
Signal |
|---|---|
Tip |
+3.3 V |
Ring 1 |
I2C SDA |
Ring 2 |
I2C SCL |
Sleeve |
GND |
To build your own temperature and humidity probe, use a Sensirion SHT3x sensor (such as the SHT31) at the default I2C address 0x44. This is the sensor StellarMate OS reads on the AUX port.
Caution
Only connect accessories designed for the StellarMate AUX port. Do not connect headphones, audio cables or other 3.5 mm devices.
3.13. Stepper Port
The stepper port drives a focuser motor directly, with no external focus controller. It uses an RJ45 connector on the power panel and a TMC2209 driver for two-phase bipolar stepper motors.
Connector |
RJ45 (8P8C) |
Driver |
TMC2209, two-phase bipolar |
Motor voltage |
Same as the input voltage (12 V nominal) |
Motor current |
Adjustable up to 1150 mA RMS per coil |
Microstepping |
1/1 to 1/256 |
The SM Pro X driver provides absolute and relative positioning, position sync, backlash compensation and reverse direction.
Danger
This is not a network port. The stepper port looks like the Ethernet port but carries motor drive voltage. Never connect a router, switch, PoE injector or any network equipment to it.
3.13.1. Pinout
Pin |
Signal |
T568B wire color |
|---|---|---|
1 |
Not connected |
White/orange |
2 |
Not connected |
Orange |
3 |
Coil 1 |
White/green |
4 |
Coil 1 |
Blue |
5 |
Coil 2 |
White/blue |
6 |
Coil 2 |
Green |
7 |
Not connected |
White/brown |
8 |
Not connected |
Brown |
Pins 3 and 4 connect to one motor coil, and pins 5 and 6 to the other. If the motor turns the wrong way, enable Reverse in the focuser settings; there is no need to rewire the cable.
3.13.2. Compatible Motors and Cables
This pinout uses the same coil pins as the RJ45 motor ports of Pegasus Astro focus controllers:
Pegasus Astro Motor Focus Kit: connect the motor with a standard straight-through RJ45 cable.
Robofocus, MoonLite, Lakeside and other DB9 motors: use an RJ45-to-DB9 adapter cable with the Robofocus pinout, such as the one available from Pegasus Astro.
6-wire unipolar motors: connect the two ends of each coil and leave the center taps unconnected. 5-wire unipolar motors cannot be used, because their coils are joined inside the motor.
Other motors: make your own cable using the pinout above. A standard Ethernet patch cable can be cut and used, with the wire colors listed in the table.
Check the coil pairs of your motor with a multimeter before connecting it. The resistance between the two wires of the same coil is a few ohms to a few tens of ohms. Wires from different coils are not connected to each other.
3.13.3. First-Time Setup
Warning
Set the motor current before moving a new motor for the first time. The default motor current is 1050 mA, which is higher than the rating of many small focuser motors. Running a motor above its rated current makes it overheat.
Start your equipment profile and open the SM Pro X driver.
In the Focuser tab, set Motor Current to the rated current of your motor or slightly lower. For example, the Pegasus Astro Motor Focus Kit v2 motor is rated at 270 mA.
Set Microstepping. The default of 1/8 suits most focusers. Higher values give smoother, quieter motion with less holding torque.
Move the focuser a short distance in and out. If it moves the wrong way, enable Reverse.
Set the maximum position and backlash for your focuser, then save the driver configuration.
3.14. Maintenance
3.14.1. Care Instructions
Use a regulated power supply with surge protection.
Keep StellarMate OS up to date for the best performance and compatibility.
Back up your settings and images regularly. See StellarMate Dashboard.
Store the unit in a cool, dry place away from direct sunlight.
Do not expose the unit to rain, dew or liquids.
Handle the unit with care and avoid impacts.
Operate the unit within its rated ambient temperature of 0 °C to 35 °C.
When bringing a cold unit indoors, let it warm up to room temperature before powering it on, so any condensation can evaporate.
Clean the enclosure with a dry, soft cloth. Do not use solvents.
Caution
Hot surface. The enclosure acts as the heat sink and may become hot during operation. Allow the unit to cool before handling it.
3.14.2. Factory Reset
A factory reset restores StellarMate OS from a recovery image stored on the unit. There are two modes:
Partial reset: restores the operating system and keeps your settings, equipment profiles and images.
Full reset: restores the operating system and erases all settings, equipment profiles and images.
Warning
A full reset permanently erases all images stored on the unit. Copy any images you want to keep before starting.
The reset button is recessed on the communication panel. You need a thin pin or paper clip (not included).
Shut down the unit and disconnect power.
Press and hold the reset button with the pin.
While holding the button, connect power.
Keep holding until you hear two short beeps repeating every 2 seconds, then release the button.
You now hear two long beeps repeating. Choose the reset mode:
Partial reset: press the button and release it immediately.
Full reset: press and hold the button for at least 3 seconds, then release it.
Rapid beeps indicate the restore is in progress. This takes a few minutes. Do not disconnect power.
A single beep indicates the restore is complete, and the unit restarts automatically.
If the restore fails, the unit returns to step 4 so you can try again. If it keeps failing, contact StellarMate Support.
3.15. Troubleshooting
3.15.1. Check the Unit Status First
SM Pro X can test itself. Connect to the same network as the unit (for example, the StellarMate hotspot), then open a web browser and go to:
http://stellarmate.local:3000/unit
The Unit Test page checks the operating system, memory, storage, network services, the power controller, KStars, EkosLive and GPS. All Systems Operational means everything passed. If a check fails, tap Details to see which service is affected, and tap Retest to run the checks again.
You can also check the status of all services on the Dashboard of the StellarMate Control Panel at http://stellarmate.local.
Note
The GPS 3D Lock check needs a view of the sky. Indoors, a GPS warning is normal.
3.15.2. Common Problems
Symptom |
Possible Cause |
Solution |
|---|---|---|
Unit does not power on (PWR LED off) |
|
|
PWR LED on, but no beeps after 60 seconds |
|
|
Unit restarts or equipment disconnects during a session |
|
|
StellarMate hotspot not visible |
|
|
Weak or unstable Wi-Fi |
|
|
StellarMate App cannot find the unit |
|
|
12 V DC output has no power |
|
|
Dew heater not warming |
|
|
Variable output has no power |
|
|
No GPS fix |
|
|
Focuser motor does not move, or vibrates |
|
|
Focuser motor gets hot |
|
|
No sensor data |
|
|
All power outputs stop working, but the unit keeps running |
|
|
Enclosure is hot to the touch |
|
|
If these steps do not solve the problem, contact StellarMate Support. Include your unit’s serial number and a screenshot of the Unit Test page.
3.16. Regulatory Information
Manufacturer: Ikarus Astronomy Co. for Scientific Instruments and Tools (Kuwait), SPC. Salmiya, Kuwait.
Support: support@stellarmate.com | https://www.stellarmate.com/support
3.16.1. FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device contains FCC ID: TX2-RTL8852CE.
3.16.2. RF Exposure
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the antennas and your body.
3.16.3. EU Declaration of Conformity
Ikarus Technologies declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. No modification that can influence the electromagnetic compatibility of the device may be made without the permission of the manufacturer.
3.16.4. Disposal
Do not dispose of this product with household waste. At the end of its life, take it to a designated collection point for the recycling of electrical and electronic equipment, in accordance with local regulations.
3.16.5. Trademarks
Ikarus Technologies and the Ikarus Technologies logo are trademarks of Ikarus Astronomy Co. for Scientific Instruments and Tools (Kuwait), SPC. StellarMate, StellarMate Plus, StellarMate Pro and StellarMate X are trademarks of Ikarus Astronomy Co. in Kuwait and/or other countries.